Turbidity Meter

Turbidity Meter
Model : TU-2016
* Range : Auto range, two ranges, 0.00 to 50.00 NTU, 50 to 1,000 NTU.
* Resolution : 0.01 NTU/1 NTU.
* Accuracy : 5 % F.S. or 0.5 NTU, which ever is greater.
* Light source : LED, 850 nm.
* Record Max, Min value.
* Power : 1.5 V battery (UM-4/AAA) x 6 PCs.
* 0 NTU and 100 NTU Calibration solution are included.
* Designed to meet ISO 7027.


Portable Infra-Red Turbidity Meter
 
Model : CyberScan TN 100 IR
 
 
Fungsi : Alat pengukur Turbidity dalam air, anti air dan praktis.

Spesifikasi :
* Principle of Operation : Nephelometric non-ratio ( conformance to ISO 7027 and DIN EN 27027)
* Turbidity Range : 0 to 1000 NTU
* Resolution : 0.01 NTU ( 0 to 19.9 NTU) ; 0.1 NTU ( 20.0 to 99.9 NTU) ; 1 NTU ( 100 to 1000 NTU)
* Accuracy : ± 2% of reading ± 1 LSD for 0 to 500 NTU; ± 3% of reading ± 1 LSD for 501 to1000 NTU
* Repeatability : ± 1% of reading or ± 0.01 NTU
* No. of Calibration Points : 4 points ( automatic)
* Response Time : 1, 000, 000 tests
* Light Source : Infrared-emitting diode ( 850nm wavelength)
* Special Functions : Auto-Ranging; Self-diagnostic
* Power Requirements : 4 x 1.4V batteries, > 200 hours


Bench Infrared Turbidity Meter
Model : CyberScan TB1000
 
Fungsi : Alat pengukur Turbidity dalam air, dapat menyimpan data, output ke komputer printer, layar yang lebar.

Spesifikasi :
* Turbidity Range : 0 to 1000 NTU
* Resolution & Accuracy : 0.01 NTU ( 0 to 9.99 NTU) ; 0.1 NTU ( 10 to 99.9 NTU) ; 1 NTU ( 100 to 1000 NTU) ; & ± 2% of Measured Range + 0.01 NTU
* Repeatability : ± 1% of Measured Range + 0.01 NTU
* No. of Calibration Points : Up to 3 points
* Calibration Options : 4 points ( 0.02, 10, 100, 1000)
* Light Source : Infrared
* Response Time : < 6 seconds
* Real-time Clock : Date and Time
* Output : RS232
* Power : 12VDC, using AC adapters 110VAC or 220VAC, 50/ 60 Hz



Portable Turbidity Meter
Model : Mi 415

Fungsi : Alat pengukur Turbidity dalam air, anti air dan praktis.

Range : 0.00 to 50.00 FNU; 50 to 1000 FNU
Resolution : 0.01 FNU; 1 FNU
Accuracy : ± 0.5 FNU or ± 5% of reading, whichever is greater
Method : detection of scattered light
Light Source : high emission infrared LED
Light Detector : silicon photocell
Environment : 0 to 50° C / 32 to 122° F; max RH 100%
Battery Type : 1 x 9V
Auto-off : after 5 minutes of non-use
Dimensions : 192 x 104 x 52 mm
Weight : 380 g

Portable Turbidimeter
Model : 2100P
 Fungsi : Alat pengukur Turbidity dalam air, dapat menyimpan data, output ke komputer printer, layar yang lebar.

Gives you lab quality results in a portable unit
• Turbidity range: 0 to 1000 NTU
• Selectable signal averaging mode compensates for fluctuations in readings caused by movement of large particles in the light path
• Pre-programmed calibration procedure, with microprocessor-controlled adjustment of calibration curve. No potentiometers to adjust
• Electronic zeroing: compensates for electronic and optical offsets. No manual adjustments are required
• Direct digital readout in NTU
• Meets or exceeds USEPA method 180.1 criteria
• Comes with six sample cells, 4 sealed vials of StablCal® Primary Turbidity Standards
Harga : Email / Fax

Portable Turbidimeter
Model : GLOBAL WATER WQ 770

Fungsi : Alat pengukur Turbidity dalam air, dapat menyimpan data, output ke komputer printer, layar yang lebar.

The Global Water Turbidity Meter combines the turbidity sensor ( described above) with a handheld meter that has a six digit LED screen, 4-button control panel, and an internal 9V battery. The handheld portable water meter can be used for environmental or process sites that do not require permanent monitoring. The meter will display readings directly in either nephelometric turbidity units ( NTU) or parts per million ( PPM) . The meter also includes an automatic shutoff feature to conserve battery power.

Range : 0-50 NTU or 0-1000 NTU
Accuracy : + 1% of full scale
Meter Resolution : 12 bit
Method : Nephelometer with correction
Operating Voltage : 10-36 VDC at 40 MS ( Sensor) ; Internal 9VDC battery ( Meter)
Current Draw : 31 mA plus sensor output ( WQ710)
Warm-up Time : 3 seconds minimum ( Sensor)
Operating Temperature : -40° to + 50° C
Materials : Black anodized aluminum, stainless steel, delrin, Sapphire optical windows, Polyurethane jacketed cable.
Pressure : 0-50 psi
Light Source : pulsed LED
Cable 102 standard ( optional to 1002)
Size Body : 1 1/ 23D x 8.53L
Sensor Shield : 1 1/ 23 x 2"
Overall Length : 93
Weight : 2 lbs
 
 


Portable Turbiditymeter
Model : 2100Q 99511-10
 
Measurement Method Ratio turbidimetric determination using a primary nephelometric light
scatter signal ( 90° ) to the transmitted light scatter signal
Regulatory Meets EPA Method 180.1
Lamp Source Tungsten filament lamp

Range 0-1000 NTU
Accuracy ± 2% of reading plus stray light from 0-1000 NTU
Repeatability ± 1% of reading or 0.01 NTU, whichever is greater
Resolution 0.01 NTU on lowest range
Stray Light = 0.02 NTU
Signal Averaging Selectable on or off
Detector Silicon Photodiode
Reading Modes Normal ( Push to Read)
Signal Averaging
Rapidly Settling Turbidity( TM)
Calibration Options Single step RapidCal( TM) for low-level regulatory reporting from 0-40 NTU
Full range calibration from 0-1000 NTU
Calibration to degrees of turbidity
Calibration Logger Records the last 25 successful calibrations
Verification Logger Logs the last 250 successful verifications
Data Logger 500 records
Power Requirement AC 100-240 V, 50/ 60 Hz ( with optional Power or USB+ Power Module)
4 AA alkaline batteries
Rechargeable NiMH ( with optional USB+ Power Module)
Operating Conditions Temperature: 0 to 50 ° C ( 32 to 122 ° F)
Relative Humidity: 0-90% at 30 ° C, 0-80% at 40 ° C, 0-70% at 50 ° C noncondensing
Storage Conditions -40 to 60 ° C ( -40 to 140 ° F) , instrument only
Interface Optional USB
Sample Required 15 mL ( 0.5 oz.)
Sample Cells Round cells, 60 x 25 mm ( 2.36 x 1 in.) , borosilicate glass with screw caps
Dimensions 22.9 x 10.7 x 7.7 cm ( 9.0 x 4.2 x 3.0 in.)
Weight 530 g ( 1.17 lb) without batteries
620 g ( 1.37 lb) with four AA alkaline batteries
Meter Enclosure Rating IP67 ( closed lid, battery and module compartment excluded)
Protection Class Power supply: Class II
Certification CE certified
 
 

Portable Turbiditymeter
Model : Micro TPW
 
Fungsi : Alat pengukur Turbidity dalam air, anti air dan praktis.

Designed to provide the ease of portability needed in the field with rugged durability, the MicroTPW is a necessity for anyone monitoring turbidity on the go. The shock-resistant carrying case holds everything necessary for field operation while the instrument itself removes easily to go wherever it is needed. With resolution of 0.01 NTU and an extended range to 1, 100 NTU, the EPA Accepted White Light MicroTPW is a perfect partner for field use.

STANDARD FEATURES: WHITE LIGHT-EPA ACCCEPTED METHOD
Rugged Self Contained Carrying Case
Contains everything needed, including battery pack, manual and calibration standards. Ensures durability and convenience regardless of where the sample needs to be taken.
Waterproof
Waterproof housing allows sample measuring and cleaning in any wet environment.
Auto Ranging 0 - 1, 100 NTU
Instrument senses turbidity level of sample and automatically adjusts to the appropriate measurement.
Simple Calibration Procedures
Calibration initiated with the push of a button ensures accurate readings.
PrimeTime Standards Kit
Each MicroTPW Turbidimeter is shipped with an HF PrimeTime Calibration kit manufactured using USEPA Accepted Primary Standard materials.
Economical Cost
Over 5000 Tests on a single set of 4 - AAA alkaline batteries.
Tungsten Lamp Life 7 - 10 years
Built in Diagnostics